Fluxomatic Corona Treaters

FTS 3000 BR Corona Treaters

Product Details:
  • Output Power: Output Power

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 3000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Schneider.

Transformer

MOC: Al Powder Coated.

Output Voltage: 10 KVolts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Pneumatic Operated Split Box Assembly

Electrodes: 100mm Rollers Covered with Silicone Sleeves driven Externally by AC Motor.

Treating Rollers: 150mm Roller with External Drive Arrangement with Motor and Drive Synchronised with Machine Line Speed.

Guide Rollers: 75mm rollers for Entry & Exit of Film.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 44 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 500 3D Corona Treaters

Product Details:
  • Output Power: 500 Watts

Specification Sheet

Treatment Width: 20-125mm.

Line Speed: 25 meters per minute.

Dyne Level: 42 Dynes/cm.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 500 Watts.

Output Frequency: 20–40 Khz.

PLC: Schneider

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil.

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 150mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings.

Pneumatic Cylinder: Two 125mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving, the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Single Phase Protection for Ozone Extraction Blower.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Corona Discharge Unit

Electrodes: Flexible Wire suitable to Treat the Moulded Articles.

Conveyor System: 1200mm MS Powder Coated Delrin Slat Chain Conveyor with Housing and Operator Safety Interlocks.

Ozone Extraction System: 1 Hp. – 3 Phase MS Powder Coated Blower. 75mm Inlet and 75mm Outlet.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 5000 Series Corona Treaters

Product Details:
  • Output Power: 4000 Watts

Specification Sheet

Treatment Width: 1500mm.

Roller Width: 1600mm.

Line Speed: 80 meters per minute.

Dyne Level: 42-44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 4000 Watts.

Output Frequency: 20–40 Khz.

PLC System with MMI Display: Unitronics or Equivalent.

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode / Key Type*.

Main Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Pneumatic Cylinder: 40mm Bore x 80 mm Stroke.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Phase Protection In the Event of any Phase Failure, the Generator will Switch Off Completely.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 16”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Guide Rollers: Two 75 mm Dynamically Balanced Aluminium Rollers

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 650 (Printing) Corona Treaters

Product Details:
  • Transformer Output Voltage: 10 K Volts.
  • GENERATOR Output Power: 750 Watts

Specification Sheet

Treatment Width: 625mm.

Roller Width: 675mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 750 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 1 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 300 CFM.

Pressure: 6”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 8000 Series Corona Treaters

Product Details:
  • Output Power: 6000 Watts

Specification Sheet

Treatment Width: 2500mm.

Roller Width: 2600mm.

Line Speed: 80 meters per minute.

Dyne Level: 44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 6000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Unitronics or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 150mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings

Pneumatic Cylinder: Two 125mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 900 CFM.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 750 (Printing) Corona Treaters

Product Details:
  • Treatment Width: 850mm.
  • Output Power: 750 Watts

Specification Sheet

Treatment Width: 850mm.

Roller Width: 850mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge:

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 750 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 1 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 300 CFM.

Pressure: 6”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.