Corona Treater

FTS 7000 Series Corona Treater

In the field of manufacturing and supplying, our company offers supreme quality FTS 7000 Series.

Specification Sheet

Treatment Width: 2100mm.

Roller Width: 2200mm.

Line Speed: 80 meters per minute.

Dyne Level: 44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: Unitronics or Equivalent.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 5000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Unitronics or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode.

Main Rollers: Two 125mm rollers covered with Pure Dielectric Silicon Sleeves with external Bearings

Pneumatic Cylinder: Two 100mm Rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 900 CFM.

Inlet: 2 x 75mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

It comes under into Corona Treater

FTS 3000 (Printing) Corona Treaters

Specification Sheet

Treatment Width: 1500mm.

Roller Width: 1600mm.

Line Speed: 80 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 3000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Schneider or Equivalent

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 25 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 75mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 12”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 1000 (Printing) Corona Treaters

Specification Sheet

Treatment Width: 1050mm.

Roller Width: 1100mm.

Line Speed: 40 meters per minute.

Dyne Level: 38 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 230VAC | Single Phase | 50Hz | 5 Amps.

Output Power: 1000 Watts.

Output Frequency: 20–40 Khz.

Transformer

MOC: Aluminium Powder Coated.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 20 Litres

Pneumatic Operated Split Box Assembly

Electrodes: SS Pipe Type Electrode/ Key Type.

Treating Rollers: Two 75mm Rollers covered with Pure Dielectric Silicon Sleeve.

Guide Rollers: Two 50mm rollers for Entry & Exit of Film.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: NA

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 2 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 500 CFM.

Pressure: 12”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 38 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

FTS 5000 BR Corona Treaters

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 6000 Watts.

Output Frequency: 20–40 Khz.

System with MMI Display: Delta Make.

Transformer

MOC: MS Powder Coated.

Output Voltage: 10 KVolts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: In the Event of any Phase Failure, the Generator will Switch Off Completely

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual/Audio Indication will be given.

Pneumatic Operated Split Box Assembly

Electrodes: Roller covered with Silicone Sleeves and driven Externally by AC Motor.

Treating Rollers: 200 mm Diameter SS 304 Roller with External Drive Arrangement with Complete Motor and Drive Synchronised with Speed of Machine.

Guide Rollers: 75mm rollers for Entry & Exit of Film.

Ozone Extraction System

Motors: 5 HP | 3 Phase | 415 V.

Inlet: 2 x 75mm.

Outlet: 100mm.

Accessories

Cables: As per Installation Requirements.

Dyne Level Pens: 44 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.

Non Conductive Film Corona Treater

In the field of manufacturing and supplying, our company offers supreme quality Non Conductive Film Corona Treater. This product manufactured by our company is wear resistant and is highly reliable in terms of the quality aspect. Our machines are made up of finest of the raw materials and are available at extremely feasible prices in the market at present.

Features:

  • Extended durability
  • Fine on performance
  • Long operational life

FTS 6000 Series Corona Treaters

Specification Sheet

Treatment Width: 1700mm.

Roller Width: 1800mm.

Line Speed: 80 meters per minute.

Dyne Level: 42-44 Dynes/cm.

No of Sides: Double.

Substrate: HDPE, LDPE, LLDPE and PP.

Gauge: 40-100 microns.

Generator

Electrical Input Requirements: 415VAC | 3Phase | 50Hz | 15 Amps.

Output Power: 4000 Watts.

Output Frequency: 20–40 Khz.

PLC System with MMI Display: Unitronics or Equivalent.

Transformer

MOC: Aluminium.

Output Voltage: 10 K Volts.

Interlocks: Spark Gap Interlock which trips the Generator when the Discharge Station High Voltage Wire Breaks during Operation.

Cooling: Transformer Oil [IS 335] | Quantity : 50 Litres

Discharge Station

Electrodes: Fin Type Electrode / Key Type*.

Main Rollers: Two 100mm Rollers covered with Pure Dielectric Silicon Sleeve.

Pneumatic Cylinder: 40mm Bore x 80 mm Stroke.

Safety Interlocks

Zero Speed System: In case the Guide or Main Roller stops moving , the Generator Trips.

Spark Protection: In case of Spark in the Electrodes, the Generator will Trip.

Phase Protection: Phase Protection In the Event of any Phase Failure, the Generator will Switch Off Completely.

Discharge Station Door Open Interlock: When the Door Opens, the Generator will trip.

No Corona Interlock: In case of No Corona, A Visual / Audio Indication will be given.

Ozone Extraction System

Motors: 3 HP | 3 Phase | 415 V | 15 Amps.

Suction Capacity: 600 CFM.

Pressure: 16”.

Inlet: 2 x 50mm.

Outlet: 75mm.

Accessories

Guide Rollers: Two 75 mm Dynamically Balanced Aluminium Rollers

Cables: As per Installation Requirements.

Dyne Level Pens: 42 Dynes Disposable Pen.

Note: Design and Specifications are subjected to change without prior notice.